Skip to content
GRIDSPEC
Verified Engineering Spec • NEC 2026 / UL 9540

Can the EcoFlow Delta 2 Max Run a Hyundai Ioniq 5 (24A Level 2 Portable EVSE)?

Live runtime simulator, solar recharge calculator and NEC / IEC breaker & cable schematic for the EcoFlow Delta 2 Max (2,048 Wh) paired with the Hyundai Ioniq 5 (24A Level 2 Portable EVSE).

Configure your system

800 W
25 ft (7.6 m)
100%
Source outlets
NEMA 5-20R
Load connection
NEMA 14-50P / L14-30P
EV range rate
≈ 18 mi (29 km) of range per hour of charging
Compatible 240V Alternative

EcoFlow Delta Pro Ultra (1 Inverter + 1 Battery) (7,200 W, 240V split-phase output) runs this load at 80% utilization.

As an Amazon Associate, we earn from qualifying purchases.

240V Split-Phase Required

Hyundai Ioniq 5 (24A Level 2 Portable EVSE) needs a 240V split-phase circuit — the EcoFlow Delta 2 Max only outputs 120V.

Wattage also falls short: 5,760 W running / 5,760 W surge vs 2,400 W / 4,800 W.

Continuous load
240%
Runtime (no sun)
—
Needs 240V output
Solar recharge
3.2 hrs
0.7 sun-days at 800 W
Min. copper wire
10 AWG
0.6% drop @ 25 ft
Overcurrent device
30A Breaker
24.0A load × 1.25 = 30.0A
Live schematic & breaker sizing diagram 120/240V Split-Phase • NEC 125% Rule
SOLAR PV INPUT 800 W PV MC4 / XT60 · MPPT POWER SOURCE / INVERTER EcoFlow Delta 2 Max 2,048 Wh • 2,400 W 4,800 W surge • 120V 240% load 30A OCPD 10 AWG Cu 24.0A @ 240V CONNECTED LOAD Hyundai Ioniq 5 (24A Level 2 Portable EVSE) 5,760 W running 5,760 W surge 240V load

Engineering report · reviewed against NEC 2026 & BS 7671:2018+A2

Engineering Breakdown: Running a Hyundai Ioniq 5 (24A Level 2 Portable EVSE) on the EcoFlow Delta 2 Max

US/NA: 240V Split-Phase Required UK/EU/AU: Continuous Overload 240% inverter utilization

When pairing the EcoFlow Delta 2 Max (2,048 Wh LiFePO4 capacity, 2,400 W continuous, 4,800 W surge) with a Hyundai Ioniq 5 (24A Level 2 Portable EVSE) (5,760 W running, 5,760 W starting surge), the system operates at 240% of continuous inverter capacity on a 240 V North American circuit and 230% on a 230 V UK/EU/AU circuit. Our North American verdict is 240V Split-Phase Required, so the runtime figures below are theoretical battery-energy values only. Wiring the connection over a 25 ft run calls for a 30 A breaker and 10 AWG copper, terminated at a NEMA 14-50P / L14-30P connection.

1. Compatibility Verdict & Inverter Load Utilization

In North American mode the Hyundai Ioniq 5 (24A Level 2 Portable EVSE) loads the EcoFlow Delta 2 Max's inverter to 240% of its 2,400 W continuous rating and 120% of its 4,800 W surge rating. The blocking issue is voltage, not just wattage: the load requires a 240 V split-phase supply while this unit outputs 120 V only. The leanest compatible alternative in our database is the EcoFlow Delta Pro Ultra (1 Inverter + 1 Battery).

CheckLoad requiresEcoFlow Delta 2 Max providesUS/NAUK/EU/AU
Continuous output 5,760 W (5,520 W @ 230V) 2,400 W Fail Fail
Start-up surge 5,760 W 4,800 W Fail Fail
Voltage 240 V / 230 V 120 V / 230 V Fail Pass
Connection NEMA 14-50P / L14-30P NEMA 5-20R UK/EU/AU: Type 2 EVSE · IEC 60309 32A Commando

An EVSE is a constant-current device: the vehicle draws exactly the current advertised by the J1772/NACS pilot signal, so the 5,760 W figure is both the running load and the start-up load — there is no motor inrush. That makes the calculation unusually clean. Because this charging profile is 240 V, the vehicle will not draw power from a 120 V-only receptacle at this current; the portable connector would need a Level 1 adapter and a 12 A limit instead. A full battery delivers about 1.6 kWh into the pack after inverter and on-board charger losses, worth roughly 5 miles (9 km) of driving at 3.5 mi/kWh.

As a portable power station, the EcoFlow Delta 2 Max integrates the LiFePO4 battery, inverter, MPPT solar controller and AC outlets in one chassis, so it can be wheeled to the load or connected to a transfer switch through its NEMA 5-20R outlet.

Compatible alternative: the EcoFlow Delta Pro Ultra (1 Inverter + 1 Battery) with the Hyundai Ioniq 5 (24A Level 2 Portable EVSE) report shows the full sizing for a unit that passes all three checks.

2. Real-World Runtime by Duty Cycle

Nameplate capacity is not usable capacity. DC-to-AC conversion, battery management overhead and cell protection reduce the 2,048 Wh rating to about 1,741 Wh of deliverable AC energy (85% system efficiency). EV charging runs at a fixed current, so the 100% row is the realistic figure; lower rows apply only if you schedule charging in intervals.

Runtime (h) = (2,048 Wh × 0.85) ÷ (5,760 W × duty cycle)
Duty cycleAverage drawRuntime (no solar)Energy per 24 h
25% 1,440 W 1.2 hrs 34.6 kWh
50% 2,880 W 36 min 69.1 kWh
65% 3,744 W 28 min 89.9 kWh
100% 5,760 W 18 min 138.2 kWh

Even at a 50% duty cycle the battery lasts 36 min, so plan on solar, grid or generator recharging for anything longer than an evening outage. Because the inverter cannot actually run this load in North American mode, treat these numbers as an energy-budget reference for a compatible inverter of the same capacity.

3. NEC 125% Breaker & Copper Wire Gauge Sizing

NEC 210.19(A) and 210.20(A) require conductors and overcurrent devices for continuous loads — anything running three hours or more, which includes EV charging and HVAC — to be rated at 125% of the load current. For this pairing: 5,760 W ÷ 240 V = 24.0 A, × 1.25 = 30.0 A, which rounds up to the next standard NEC 240.6 size of 30 A. The conductor must be protected by that breaker (75 °C ampacity at least 30 A) and keep round-trip voltage drop at or below 3%, so longer runs are upsized.

Breaker ≥ (5,760 W ÷ 240 V) × 1.25 = 30.0 A → 30 A
Voltage drop % = (2 × L × I × R) ÷ V × 100

North America (NEC, THHN copper, 75 °C)

One-way distanceBreakerMin. copperVoltage dropNote
25 ft (7.6 m) 30 A 10 AWG 0.60% Sized by ampacity
50 ft (15.2 m) 30 A 10 AWG 1.21% Sized by ampacity
75 ft (22.9 m) 30 A 10 AWG 1.81% Sized by ampacity
100 ft (30.5 m) 30 A 10 AWG 2.42% Sized by ampacity

UK / EU / Australia (IEC 60364 / BS 7671, PVC copper, method C)

IEC-based codes size protection by design current rather than a blanket 125% multiplier: Ib ≤ In ≤ Iz. At 230 V the load draws 24.0 A (the EVSE's 24 A pilot current at 230 V), so a 25 A Type B/C MCB with RCD protection applies. In the UK, BS 7671 Section 722 additionally requires a dedicated circuit and Type A or Type B RCD for EV charge points.

One-way distanceMCBMin. cableVoltage drop
7.5 m (25 ft) 25 A 2.5 mm² 1.16%
15 m (49 ft) 25 A 2.5 mm² 2.32%
22.5 m (74 ft) 25 A 4.0 mm² 2.16%
30 m (98 ft) 25 A 4.0 mm² 2.89%

Because the current is modest, 10 AWG copper stays within the voltage-drop target all the way to 100 ft.

4. Solar Array Recharge Time Breakdown

The EcoFlow Delta 2 Max accepts up to 1,000 W of photovoltaic input. Real arrays rarely deliver nameplate output, so we apply an 80% harvest factor for MPPT conversion, cell temperature and soiling, and convert hours to days using 4.5 peak-sun-hours — a conservative annual average for the US, southern Europe and Australia (UK winters can fall below 1.5).

PV arrayReal harvest0–100% rechargeSun-days @ 4.5 PSHNet with load @ 50%
400 W 320 W 6.4 hrs 1.4 −2,560 W
800 W 640 W 3.2 hrs 0.7 −2,240 W
1,000 W 800 W 2.6 hrs 0.6 −2,080 W

A typical 800 W portable array refills the battery in about 3.2 hrs of strong sun, while maxing out the 1,000 W input cuts that to 2.6 hrs. To fully offset the Hyundai Ioniq 5 (24A Level 2 Portable EVSE) at a 50% duty cycle (2,880 W average) during daylight you need roughly 3,600 W of panels, which exceeds this unit's 1,000 W input limit — solar can slow the drain but not eliminate it.

5. Frequently Asked Questions

Can the EcoFlow Delta 2 Max run a Hyundai Ioniq 5 (24A Level 2 Portable EVSE)?

Not reliably in North America — our verdict is "240V Split-Phase Required". The load needs 240 V split-phase power and the EcoFlow Delta 2 Max outputs 120 V only. The EcoFlow Delta Pro Ultra (1 Inverter + 1 Battery) is a compatible alternative. In UK/EU/AU 230 V mode the verdict is "Continuous Overload".

How many miles of range can the EcoFlow Delta 2 Max add to a Hyundai Ioniq 5?

A full 2,048 Wh charge delivers about 1.6 kWh to the vehicle battery after inverter (85%) and on-board charger (90%) losses — roughly 5 miles at 3.5 mi/kWh. Charging at this profile is not possible on this unit without reducing current or changing voltage.

What breaker and wire size do I need to connect a Hyundai Ioniq 5 (24A Level 2 Portable EVSE) to the EcoFlow Delta 2 Max?

In the US, 5,760 W at 240 V is 24.0 A; applying the NEC 125% continuous-load rule gives 30.0 A, so use a 30 A breaker and 10 AWG copper for runs up to 25 ft (0.6% voltage drop). In 230 V markets the load draws 24.0 A, protected by a 25 A MCB on 2.5 mm² cable for runs up to 7.5 m. Receptacle: NEMA 14-50P / L14-30P (US) or Type 2 EVSE · IEC 60309 32A Commando (UK/EU/AU).

How long does it take to recharge the EcoFlow Delta 2 Max with solar panels?

With an 800 W array and an 80% real-world harvest factor, a full recharge takes about 3.2 hrs of peak sun (0.7 days at 4.5 peak-sun-hours). At its maximum 1,000 W solar input it drops to 2.6 hrs.

Methodology & safety note

Specifications come from manufacturer datasheets in our open dataset; ampacity and resistance values follow NEC Table 310.16 and Chapter 9 Table 8, and BS 7671 Appendix 4. Calculations assume copper conductors, 30 °C ambient and no bundling derating. Inverter-to-panel connections require a listed transfer switch or interlock to prevent back-feeding the grid. These results are an engineering estimate, not a substitute for a licensed electrician and local permit. See our methodology and safety disclaimer.

Status dots show the North American verdict: compatible, conditional, not compatible.

Other loads on the EcoFlow Delta 2 Max

All 50 loads on the EcoFlow Delta 2 Max →

Other power stations for the Hyundai Ioniq 5 (24A Level 2 Portable EVSE)

Compare every source for this load →

More Electric Vehicle Charging on the EcoFlow Delta 2 Max