Can the Fox ESS EP5 Modular Hybrid Run a Ventless All-in-One Washer & Heat Pump Dryer (120V)?

Live runtime simulator, solar recharge calculator and NEC / IEC breaker & cable schematic for the Fox ESS EP5 Modular Hybrid (5,180 Wh) paired with the Ventless All-in-One Washer & Heat Pump Dryer (120V).

Configure your system

800 W
7.6 m (25 ft)
50%
Source outlets
Hardwired consumer unit (RCBO protected)
Load connection
BS 1363 13A / Schuko CEE 7/4 / AS/NZS 3112 10A
Verified Hardware Match

Check current bundle pricing for the Fox ESS EP5 Modular Hybrid plus a changeover switch kit for this setup.

As an Amazon Associate, we earn from qualifying purchases.

Verified Compatible

Fox ESS EP5 Modular Hybrid handles 950 W continuous and 1,400 W surge with headroom.

4,050 W of continuous capacity left for other circuits.

Continuous load
19%
Runtime (no sun)
9.3 hrs
50% duty · 85% inverter eff.
Solar recharge
8.1 hrs
1.8 sun-days at 800 W
Min. copper wire
1.5 mm²
0.3% drop @ 7.6 m
Overcurrent device
6A MCB
4.1A load × 1.00 = 4.1A
Live schematic & breaker sizing diagram 230V AC • IEC 60364
SOLAR PV INPUT 800 W PV MC4 / XT60 · MPPT POWER SOURCE / INVERTER Fox ESS EP5 Modular Hybrid 5,180 Wh • 5,000 W 7,500 W surge • 120/240V 19% load 6A MCB 1.5 mm² Cu 4.1A @ 230V CONNECTED LOAD Ventless All-in-One Washer & Heat Pump Dr… 950 W running 1,400 W surge 230V load

Engineering report · reviewed against NEC 2026 & BS 7671:2018+A2

Engineering Breakdown: Running a Ventless All-in-One Washer & Heat Pump Dryer (120V) on the Fox ESS EP5 Modular Hybrid

UK/EU/AU: Verified Compatible 19% inverter utilization Sold in UK / EU / AU only

When pairing the Fox ESS EP5 Modular Hybrid (5,180 Wh LiFePO4 capacity, 5,000 W continuous, 7,500 W surge) with a Ventless All-in-One Washer & Heat Pump Dryer (120V) (950 W running, 1,400 W starting surge), the system operates at 19% of continuous inverter capacity on a 230 V UK/EU/AU circuit. At a 100% duty cycle and 85% inverter efficiency, a full battery delivers roughly 4.6 hrs of off-grid runtime. Wiring the connection over a 7.5 m run calls for a 6 A MCB and 1.5 mm² copper, terminated at a BS 1363 13A / Schuko CEE 7/4 / AS/NZS 3112 10A connection.

1. Compatibility Verdict & Inverter Load Utilization

In UK/EU/AU 230 V mode the Ventless All-in-One Washer & Heat Pump Dryer (120V) loads the Fox ESS EP5 Modular Hybrid's inverter to 19% of its 5,000 W continuous rating and 19% of its 7,500 W surge rating. Both figures are under the 80% sustained-load guideline, so this is a comfortable, verified match with 4,050 W of spare capacity for lights, a router or a refrigerator on the same unit.

CheckLoad requiresFox ESS EP5 Modular Hybrid providesUK/EU/AU
Continuous output 950 W 5,000 W Pass
Start-up surge 1,400 W 7,500 W Pass
Voltage 230 V 230 V Pass
Connection BS 1363 13A / Schuko CEE 7/4 / AS/NZS 3112 10A Hardwired consumer unit (RCBO protected)

Compressor appliances such as refrigerators and freezers draw very little on average — 950 W while running — but need 1,400 W for a moment each time the compressor kicks on. Their duty cycle is typically 30–40%, which is why a modest battery can keep food safe for a long time. The Fox ESS EP5 Modular Hybrid's 7,500 W surge rating comfortably handles each restart.

The Fox ESS EP5 Modular Hybrid combines a hybrid solar inverter with stackable battery modules, wired permanently into the home's distribution board. Its 6,500 W PV input lets one unit handle both rooftop solar and storage.

2. Real-World Runtime by Duty Cycle

Nameplate capacity is not usable capacity. DC-to-AC conversion, battery management overhead and cell protection reduce the 5,180 Wh rating to about 4,403 Wh of deliverable AC energy (85% system efficiency). Duty cycle is the share of each hour the load actually draws its running power — thermostats, pressure switches and intermittent use all lower it.

Runtime (h) = (5,180 Wh × 0.85) ÷ (950 W × duty cycle)
Duty cycleAverage drawRuntime (no solar)Energy per 24 h
25% 238 W 18.5 hrs 5.7 kWh
50% 475 W 9.3 hrs 11.4 kWh
65% 618 W 7.1 hrs 14.8 kWh
100% 950 W 4.6 hrs 22.8 kWh

Even at a 50% duty cycle the battery lasts 9.3 hrs, so plan on solar, grid or generator recharging for anything longer than an evening outage.

3. BS 7671 / IEC 60364 Breaker & Cable Sizing

IEC-based codes size protection by design current rather than a blanket 125% multiplier: Ib ≤ In ≤ Iz. At 230 V the load draws 4.1 A, so a 6 A Type B/C MCB with RCD protection applies. In the UK, BS 7671 Section 722 additionally requires a dedicated circuit and Type A or Type B RCD for EV charge points.

One-way distanceMCBMin. cableVoltage drop
7.5 m (25 ft) 6 A 1.5 mm² 0.33%
15 m (49 ft) 6 A 1.5 mm² 0.65%
22.5 m (74 ft) 6 A 1.5 mm² 0.98%
30 m (98 ft) 6 A 1.5 mm² 1.30%

Because the current is modest, 1.5 mm² copper stays within the voltage-drop target all the way to 30 m.

4. Solar Array Recharge Time Breakdown

The Fox ESS EP5 Modular Hybrid accepts up to 6,500 W of photovoltaic input. Real arrays rarely deliver nameplate output, so we apply an 80% harvest factor for MPPT conversion, cell temperature and soiling, and convert hours to days using 4.5 peak-sun-hours — a conservative annual average for the US, southern Europe and Australia (UK winters can fall below 1.5).

PV arrayReal harvest0–100% rechargeSun-days @ 4.5 PSHNet with load @ 50%
800 W 640 W 8.1 hrs 1.8 +165 W
1,600 W 1,280 W 4.0 hrs 0.9 +805 W
3,000 W 2,400 W 2.2 hrs 0.5 +1,925 W
6,000 W 4,800 W 1.1 hrs 0.2 +4,325 W
6,500 W 5,200 W 60 min 0.2 +4,725 W

A typical 800 W portable array refills the battery in about 8.1 hrs of strong sun, while maxing out the 6,500 W input cuts that to 60 min. To fully offset the Ventless All-in-One Washer & Heat Pump Dryer (120V) at a 50% duty cycle (475 W average) during daylight you need roughly 600 W of panels, which this unit can accept.

5. Frequently Asked Questions

Can the Fox ESS EP5 Modular Hybrid run a Ventless All-in-One Washer & Heat Pump Dryer (120V)?

Yes. The Fox ESS EP5 Modular Hybrid delivers 5,000 W continuous and 7,500 W surge, covering the Ventless All-in-One Washer & Heat Pump Dryer (120V)'s 950 W running and 1,400 W start-up draw at 19% inverter utilization.

How long will the Fox ESS EP5 Modular Hybrid run a Ventless All-in-One Washer & Heat Pump Dryer (120V)?

With 5,180 Wh of capacity and 85% inverter efficiency, expect about 4.6 hrs of continuous operation and 9.3 hrs at a 50% duty cycle. Adding solar input during the day extends this further.

What breaker and wire size do I need to connect a Ventless All-in-One Washer & Heat Pump Dryer (120V) to the Fox ESS EP5 Modular Hybrid?

At 230 V the load draws 4.1 A. Under BS 7671 / IEC 60364 the protective device must be at least the design current (Ib ≤ In ≤ Iz), so use a 6 A MCB with RCD protection on 1.5 mm² copper cable for runs up to 7.5 m (0.3% voltage drop). Connection: BS 1363 13A / Schuko CEE 7/4 / AS/NZS 3112 10A.

How long does it take to recharge the Fox ESS EP5 Modular Hybrid with solar panels?

With an 800 W array and an 80% real-world harvest factor, a full recharge takes about 8.1 hrs of peak sun (1.8 days at 4.5 peak-sun-hours). At its maximum 6,500 W solar input it drops to 60 min.

Methodology & safety note

Specifications come from manufacturer datasheets in our open dataset; ampacity and resistance values follow NEC Table 310.16 and Chapter 9 Table 8, and BS 7671 Appendix 4. Calculations assume copper conductors, 30 °C ambient and no bundling derating. Inverter-to-panel connections require a listed transfer switch or interlock to prevent back-feeding the grid. These results are an engineering estimate, not a substitute for a licensed electrician and local permit. See our methodology and safety disclaimer.

Status dots show the UK/EU/AU verdict: compatible, conditional, not compatible.