Skip to content
GRIDSPEC
Verified Engineering Spec • IEC 60364 / BS 7671

Can the Selectronic SP Pro AU Off-Grid Inverter Run a Rivian R1T / R1S (24A Portable Charger)?

Live runtime simulator, solar recharge calculator and NEC / IEC breaker & cable schematic for the Selectronic SP Pro AU Off-Grid Inverter (10,240 Wh) paired with the Rivian R1T / R1S (24A Portable Charger).

Configure your system

800 W
7.6 m (25 ft)
100%
Source outlets
Hardwired consumer unit (RCBO protected)
Load connection
Type 2 EVSE · IEC 60309 32A Commando
EV range rate
≈ 17 mi (28 km) of range per hour of charging
Verified Hardware Match

Check current bundle pricing for the Selectronic SP Pro AU Off-Grid Inverter plus a changeover switch kit for this setup.

As an Amazon Associate, we earn from qualifying purchases.

Verified Compatible

Selectronic SP Pro AU Off-Grid Inverter handles 5,520 W continuous and 5,520 W surge with headroom.

1,980 W of continuous capacity left for other circuits.

Continuous load
74%
Runtime (no sun)
1.6 hrs
100% duty · 85% inverter eff.
Solar recharge
16.0 hrs
3.6 sun-days at 800 W
Min. copper wire
2.5 mm²
1.2% drop @ 7.6 m
Overcurrent device
25A MCB
24.0A load × 1.00 = 24.0A
Live schematic & breaker sizing diagram 230V AC • IEC 60364
SOLAR PV INPUT 800 W PV MC4 / XT60 · MPPT POWER SOURCE / INVERTER Selectronic SP Pro AU Off-Grid Inverter 10,240 Wh • 7,500 W 22,500 W surge • 120/240V 74% load 25A MCB 2.5 mm² Cu 24.0A @ 230V CONNECTED LOAD Rivian R1T / R1S (24A Portable Charger) 5,520 W running 5,520 W surge 230V load

Engineering report · reviewed against NEC 2026 & BS 7671:2018+A2

Engineering Breakdown: Running a Rivian R1T / R1S (24A Portable Charger) on the Selectronic SP Pro AU Off-Grid Inverter

UK/EU/AU: Verified Compatible 74% inverter utilization Sold in UK / EU / AU only

When pairing the Selectronic SP Pro AU Off-Grid Inverter (10,240 Wh LiFePO4 capacity, 7,500 W continuous, 22,500 W surge) with a Rivian R1T / R1S (24A Portable Charger) (5,760 W running, 5,760 W starting surge), the system operates at 74% of continuous inverter capacity on a 230 V UK/EU/AU circuit. At a 100% duty cycle and 85% inverter efficiency, a full battery delivers roughly 1.6 hrs of off-grid runtime. Wiring the connection over a 7.5 m run calls for a 25 A MCB and 2.5 mm² copper, terminated at a Type 2 EVSE · IEC 60309 32A Commando connection.

1. Compatibility Verdict & Inverter Load Utilization

In UK/EU/AU 230 V mode the Rivian R1T / R1S (24A Portable Charger) loads the Selectronic SP Pro AU Off-Grid Inverter's inverter to 74% of its 7,500 W continuous rating and 25% of its 22,500 W surge rating. Both figures are under the 80% sustained-load guideline, so this is a comfortable, verified match with 1,980 W of spare capacity for lights, a router or a refrigerator on the same unit.

CheckLoad requiresSelectronic SP Pro AU Off-Grid Inverter providesUK/EU/AU
Continuous output 5,520 W 7,500 W Pass
Start-up surge 5,520 W 22,500 W Pass
Voltage 230 V 230 V Pass
Connection Type 2 EVSE · IEC 60309 32A Commando Hardwired consumer unit (RCBO protected)

An EVSE is a constant-current device: the vehicle draws exactly the current advertised by the J1772/NACS pilot signal, so the 5,760 W figure is both the running load and the start-up load — there is no motor inrush. That makes the calculation unusually clean. If you want to stay under the 80% sustained-load guideline, set the charge current in the vehicle app to 25 A or less, which keeps the Selectronic SP Pro AU Off-Grid Inverter at roughly 6,000 W. A full battery delivers about 7.8 kWh into the pack after inverter and on-board charger losses, worth roughly 27 miles (44 km) of driving at 3.5 mi/kWh.

The Selectronic SP Pro AU Off-Grid Inverter is a heavy-duty off-grid inverter-charger built for rural properties, with a surge rating of 22,500 W — 3.0× its continuous output — designed to start bore pumps, workshop compressors and other large motors.

2. Real-World Runtime by Duty Cycle

Nameplate capacity is not usable capacity. DC-to-AC conversion, battery management overhead and cell protection reduce the 10,240 Wh rating to about 8,704 Wh of deliverable AC energy (85% system efficiency). EV charging runs at a fixed current, so the 100% row is the realistic figure; lower rows apply only if you schedule charging in intervals.

Runtime (h) = (10,240 Wh × 0.85) ÷ (5,520 W × duty cycle)
Duty cycleAverage drawRuntime (no solar)Energy per 24 h
25% 1,380 W 6.3 hrs 33.1 kWh
50% 2,760 W 3.2 hrs 66.2 kWh
65% 3,588 W 2.4 hrs 86.1 kWh
100% 5,520 W 1.6 hrs 132.5 kWh

Even at a 50% duty cycle the battery lasts 3.2 hrs, so plan on solar, grid or generator recharging for anything longer than an evening outage.

3. BS 7671 / IEC 60364 Breaker & Cable Sizing

IEC-based codes size protection by design current rather than a blanket 125% multiplier: Ib ≤ In ≤ Iz. At 230 V the load draws 24.0 A (the EVSE's 24 A pilot current at 230 V), so a 25 A Type B/C MCB with RCD protection applies. In the UK, BS 7671 Section 722 additionally requires a dedicated circuit and Type A or Type B RCD for EV charge points.

One-way distanceMCBMin. cableVoltage drop
7.5 m (25 ft) 25 A 2.5 mm² 1.16%
15 m (49 ft) 25 A 2.5 mm² 2.32%
22.5 m (74 ft) 25 A 4.0 mm² 2.16%
30 m (98 ft) 25 A 4.0 mm² 2.89%

Moving the Selectronic SP Pro AU Off-Grid Inverter from 7.5 m to 30 m away forces the conductor up from 2.5 mm² to 4.0 mm² — park the unit as close to the load as ventilation and weather protection allow.

4. Solar Array Recharge Time Breakdown

The Selectronic SP Pro AU Off-Grid Inverter accepts up to 8,000 W of photovoltaic input. Real arrays rarely deliver nameplate output, so we apply an 80% harvest factor for MPPT conversion, cell temperature and soiling, and convert hours to days using 4.5 peak-sun-hours — a conservative annual average for the US, southern Europe and Australia (UK winters can fall below 1.5).

PV arrayReal harvest0–100% rechargeSun-days @ 4.5 PSHNet with load @ 50%
800 W 640 W 16.0 hrs 3.6 −2,120 W
1,600 W 1,280 W 8.0 hrs 1.8 −1,480 W
3,000 W 2,400 W 4.3 hrs 0.9 −360 W
6,000 W 4,800 W 2.1 hrs 0.5 +2,040 W
8,000 W 6,400 W 1.6 hrs 0.4 +3,640 W

A typical 800 W portable array refills the battery in about 16.0 hrs of strong sun, while maxing out the 8,000 W input cuts that to 1.6 hrs. To fully offset the Rivian R1T / R1S (24A Portable Charger) at a 50% duty cycle (2,760 W average) during daylight you need roughly 3,450 W of panels, which this unit can accept.

5. Frequently Asked Questions

Can the Selectronic SP Pro AU Off-Grid Inverter run a Rivian R1T / R1S (24A Portable Charger)?

Yes. The Selectronic SP Pro AU Off-Grid Inverter delivers 7,500 W continuous and 22,500 W surge, covering the Rivian R1T / R1S (24A Portable Charger)'s 5,520 W running and 5,520 W start-up draw at 74% inverter utilization.

How many miles of range can the Selectronic SP Pro AU Off-Grid Inverter add to a Rivian R1T / R1S?

A full 10,240 Wh charge delivers about 7.8 kWh to the vehicle battery after inverter (85%) and on-board charger (90%) losses — roughly 27 miles at 3.5 mi/kWh. At the full 5,520 W charge rate that takes 1.6 hrs.

What breaker and wire size do I need to connect a Rivian R1T / R1S (24A Portable Charger) to the Selectronic SP Pro AU Off-Grid Inverter?

At 230 V the load draws 24.0 A. Under BS 7671 / IEC 60364 the protective device must be at least the design current (Ib ≤ In ≤ Iz), so use a 25 A MCB with RCD protection on 2.5 mm² copper cable for runs up to 7.5 m (1.2% voltage drop). Connection: Type 2 EVSE · IEC 60309 32A Commando.

How long does it take to recharge the Selectronic SP Pro AU Off-Grid Inverter with solar panels?

With an 800 W array and an 80% real-world harvest factor, a full recharge takes about 16.0 hrs of peak sun (3.6 days at 4.5 peak-sun-hours). At its maximum 8,000 W solar input it drops to 1.6 hrs.

Methodology & safety note

Specifications come from manufacturer datasheets in our open dataset; ampacity and resistance values follow NEC Table 310.16 and Chapter 9 Table 8, and BS 7671 Appendix 4. Calculations assume copper conductors, 30 °C ambient and no bundling derating. Inverter-to-panel connections require a listed transfer switch or interlock to prevent back-feeding the grid. These results are an engineering estimate, not a substitute for a licensed electrician and local permit. See our methodology and safety disclaimer.

Status dots show the UK/EU/AU verdict: compatible, conditional, not compatible.

Other loads on the Selectronic SP Pro AU Off-Grid Inverter

All 50 loads on the Selectronic SP Pro AU Off-Grid Inverter →

Other power stations for the Rivian R1T / R1S (24A Portable Charger)

Compare every source for this load →

More Electric Vehicle Charging on the Selectronic SP Pro AU Off-Grid Inverter