Skip to content
GRIDSPEC

Pumps & Water Systems · Load hub

Which Power Stations Can Run a 1.0 HP Deep Well Submersible Pump (240V)?

All 30 portable power stations, home batteries and hybrid inverters in the GridSpec database, ranked by compatibility and runtime for the 1.0 HP Deep Well Submersible Pump (240V).

Electrical profile

Running power
1,650 W
Starting surge
4,500 W (2.7×)
US/NA voltage
240 V
UK/EU/AU voltage
230 V
US connection
NEMA L14-30P / Hardwired
UK/EU/AU connection
Hardwired via DP isolator · IEC 60309 32A
NEC breaker
15 A
IEC MCB
10 A

Sizing summary

The 1.0 HP Deep Well Submersible Pump (240V) draws 1,650 W while running and 4,500 W at start-up — a surge ratio of 2.7×, typical of induction motors and compressors, which makes inverter surge rating the deciding factor. In North America it is a 240 V load, so only split-phase-capable units qualify: 18 otherwise-capable 120 V units are excluded on voltage alone.

12 of 30 sources pass every check in North America and 28 of 35 pass in 230 V markets. The leanest fully compatible choice is the Zendure SuperBase V6400 , while the EG4 18kPV Hybrid Inverter + PowerPro 14.3kWh WallMount delivers the longest runtime (24.6 hrs at 30% duty) .

Every power source ranked for the 1.0 HP Deep Well Submersible Pump (240V)

Power source Capacity / output US/NA verdict UK/EU/AU verdict Load Runtime @ 30%
EG4 18kPV Hybrid Inverter + PowerPro 14.3kWh WallMount 14,336 Wh / 12,000 W Verified Compatible Verified Compatible 14% 24.6 hrs Full report →
Tesla Powerwall 3 13,500 Wh / 11,500 W Verified Compatible Verified Compatible 14% 23.2 hrs Full report →
EG4 6000XP Off-Grid Inverter + 10.2kWh Server Rack 10,240 Wh / 6,000 W Verified Compatible Verified Compatible 28% 17.6 hrs Full report →
Selectronic SP Pro AU Off-Grid Inverter UK / EU / AU only 10,240 Wh / 7,500 W Not sold Verified Compatible 22% 17.6 hrs Full report →
Enphase IQ Battery 5P (Dual 10kWh Bank) 10,000 Wh / 7,680 W Verified Compatible Verified Compatible 21% 17.2 hrs Full report →
Bluetti EP800 + 2x B500 Home System 9,920 Wh / 7,600 W Verified Compatible Verified Compatible 22% 17.0 hrs Full report →
Sungrow SH10RS Hybrid Inverter + Battery UK / EU / AU only 9,600 Wh / 10,000 W Not sold Verified Compatible 17% 16.5 hrs Full report →
Sigenergy SigenStor 5-in-1 System UK / EU / AU only 8,000 Wh / 8,000 W Not sold Verified Compatible 21% 13.7 hrs Full report →
Zendure SuperBase V6400 6,438 Wh / 3,800 W Verified Compatible Verified Compatible 43% 11.1 hrs Full report →
EcoFlow Delta Pro Ultra (1 Inverter + 1 Battery) 6,144 Wh / 7,200 W Verified Compatible Verified Compatible 23% 10.6 hrs Full report →
Fox ESS EP5 Modular Hybrid UK / EU / AU only 5,180 Wh / 5,000 W Not sold Verified Compatible 33% 8.9 hrs Full report →
Oukitel BP5000 Pro Max 5,120 Wh / 5,000 W Verified Compatible Verified Compatible 33% 8.8 hrs Full report →
myenergi Libbi (5kW Inverter + 5kWh Battery) UK / EU / AU only 5,120 Wh / 5,000 W Not sold Verified Compatible 33% 8.8 hrs Full report →
Jackery Explorer 5000 Plus 5,040 Wh / 7,200 W Verified Compatible Verified Compatible 23% 8.7 hrs Full report →
EcoFlow Delta Pro 3 4,096 Wh / 4,000 W Verified Compatible Verified Compatible 41% 7.0 hrs Full report →
Anker SOLIX F3800 3,840 Wh / 6,000 W Verified Compatible Verified Compatible 28% 6.6 hrs Full report →
Anker SOLIX F3800 Plus 3,840 Wh / 6,000 W Verified Compatible Verified Compatible 28% 6.6 hrs Full report →
Victron MultiPlus-II 48/5000 + 10kWh LiFePO4 Bank 10,240 Wh / 4,000 W 240V Split-Phase Required Verified Compatible 41% — Full report →
Goal Zero Yeti PRO 4000 3,993 Wh / 3,600 W 240V Split-Phase Required Verified Compatible 46% — Full report →
Fossibot F3600 Pro 3,840 Wh / 3,600 W 240V Split-Phase Required Verified Compatible 46% — Full report →
EcoFlow Delta Pro (Gen 1) 3,600 Wh / 3,600 W 240V Split-Phase Required Verified Compatible 46% — Full report →
Mango Power E (3.5kWh LFP) 3,530 Wh / 3,000 W 240V Split-Phase Required Verified Compatible 55% — Full report →
Bluetti AC500 + B300S 3,072 Wh / 5,000 W 240V Split-Phase Required Verified Compatible 33% — Full report →
Pecron E3600LFP 3,072 Wh / 3,600 W 240V Split-Phase Required Verified Compatible 46% — Full report →
Jackery Explorer 3000 Pro 3,024 Wh / 3,000 W 240V Split-Phase Required Verified Compatible 55% — Full report →
Bluetti AC300 + B300K 2,764 Wh / 3,000 W 240V Split-Phase Required Verified Compatible 55% — Full report →
Anker SOLIX F2600 2,560 Wh / 2,400 W 240V Split-Phase Required Surge Overload 69% — Full report →
EcoFlow Delta 2 Max 2,048 Wh / 2,400 W 240V Split-Phase Required Verified Compatible 69% — Full report →
Anker SOLIX F2000 (PowerHouse 767) 2,048 Wh / 2,400 W 240V Split-Phase Required Surge Overload 69% — Full report →
Bluetti AC200L 2,048 Wh / 2,400 W 240V Split-Phase Required Surge Overload 69% — Full report →
Jackery Explorer 2000 Plus 2,042 Wh / 3,000 W 240V Split-Phase Required Verified Compatible 55% — Full report →
Bluetti AC240 (IP65 Weatherproof) 1,536 Wh / 2,400 W 240V Split-Phase Required Surge Overload 69% — Full report →
Jackery Explorer 1000 v2 1,070 Wh / 1,500 W 240V Split-Phase Required Continuous Overload 110% — Full report →
Anker SOLIX C1000 1,056 Wh / 1,800 W 240V Split-Phase Required Surge Overload 92% — Full report →
EcoFlow Delta 3 Plus 1,024 Wh / 1,800 W 240V Split-Phase Required Surge Overload 92% — Full report →

Frequently asked questions

What size power station do I need for a 1.0 HP Deep Well Submersible Pump (240V)?

You need at least 1,650 W of continuous inverter output, 4,500 W of surge capacity and 120/240 V split-phase output in North America. 12 of the 30 power sources we track meet all three requirements; the leanest is the Zendure SuperBase V6400.

Which power station runs a 1.0 HP Deep Well Submersible Pump (240V) the longest?

The EG4 18kPV Hybrid Inverter + PowerPro 14.3kWh WallMount offers the longest runtime among compatible units: about 24.6 hrs at a 30% duty cycle thanks to its 14,336 Wh battery.

What breaker does a 1.0 HP Deep Well Submersible Pump (240V) need?

In North America: 6.9 A at 240 V × 1.25 = 8.6 A, so a 15 A breaker. In the UK, EU and Australia: 7.2 A at 230 V on a 10 A MCB with RCD protection.